What's actually happening when your mini-split drips indoors
Your mini-split's indoor head does two jobs at once. It cools the air, and it pulls moisture out of it. On a humid summer day, that moisture adds up to a surprising amount of water, sometimes a gallon or more in an afternoon.
All that water collects in a small pan under the coil and drains out through a thin hose, usually 5/8 inch, that runs down and out through the wall by gravity. No pump on most units. Just a gentle downhill slope.
When water shows up on your floor or running down the wall below the head, it means that drain path isn't keeping up. The pan fills and spills over the front lip of the unit.
The good news: this is one of the most DIY-friendly mini-split problems there is. Most people clear it in under an hour with a shop vac and a bottle of vinegar.
The bad news: if you ignore it, the water finds your drywall and flooring, and summer humidity turns that into mold fast.
The usual suspects, in order
Start with the drain line. A clogged condensate drain causes the vast majority of summer indoor drips Techs get called on. Algae and dust build a slimy plug inside that skinny hose, and once it seals off, the pan overflows within an hour of running.
Right behind it: dirty filters. They restrict airflow so badly that the coil either freezes or sweats heavily. People are shocked how much difference a rinse makes, and it's free.
A frozen coil is the sneaky one. It looks like a drain problem because you get a flood of water, but it's really an airflow or refrigerant issue. If you open the cover and see ice, that's your answer.
A unit that's not hung level will drip even with a clear drain. Water pools on the wrong side of the pan and creeps out the front. Less common, but you'll see it on DIY installs.
Loose drain fittings and dead condensate pumps round out the list. Both are real but rarer. You'll only have a pump if your installer used one because gravity drainage wasn't possible at that location.
- Clogged drain line: most common by far, cheap fix
- Dirty filters: free fix, often the root cause
- Frozen coil: looks like a drain issue, usually isn't
- Unit not level: check with a small level on top
- Loose drain fitting: quick reseat if you can reach it
- Failed condensate pump: only if your unit has one